ABOUT ME

-

Today
-
Yesterday
-
Total
-
  • Mortuary refrigerator
    Mortuary refrigerators 2023. 1. 9. 12:54

    Fabrication Specification for Mortuary Refrigerator of Busung Freezer Industrial Co., Ltd.

    1) Casing

    - The material is used 1.2T of electric galvanized steel sheet (EGI) which has mechanical feature,

       hardness, flexure, shape, dimension and thickness. These are in accordance with KSD 3528

    - The coating method is spray coating with a coating film thickness of 20μ ±1 using powder coating. Dry for

      20 minutes at    a temperature of 130 .

    - The standard color is ivory.

    - It should be easy assembling structure. In case of A/S, it should be manufactured easy disassembling for

       the repairing in convenience.  

    2) Condenser

    -The thermocouple must be a seamless phosphorus deoxidized copper tube (KSD 5301) or equivalent

      with a purity of 99% or higher, and there should be the uniformity of the copper tube and no harmful

      defects in use.

    - As for the copper tube and the FIN, these are mechanically expanded and closely contacted so that they

      have sufficient thermal contact surface.

    - It uses the FIN which is 0.11T of Aluminum foil with a purity of 99.9% or more. 

      It should be coated with thermosetting resin on FIN in order to improve excellent corrosion resistance and

      thermal efficiency.

    - It should be implemented for the pressure test at 37.5kg/cm2.G, and the airtight test at a pressure of

      25kg/cm2.G or above. There should be no abnormalities such as leakage and deformation.

    3) Hermetic reciprocating compressor (Compressor)

    - The compressor is an internationally verified hermetic compressor.

    - Use alternative refrigerants R-134 and R-404 for refrigerant.

    - When connecting the compressor with pipe, the welding area is 

      coated with an anticorrosion paint, and wiring use a contactor.

    - To protect the winding of the compressor motor, it is used the Compressor

      overload relay F.O.C.R or the overload protector MPDULE to prevent from the damage to the motor.

    - When assembling the compressor with the base, vibration-proof rubber and vibration-proof spring are

      used to prevent from the vibration.

    - It is installed a CHARGE NIPPLE on the compressor for refrigerant supplement and air tightness test.

    - Make sure to drive the compressor at about 70% of the maximum load.

    4) Fan for condenser

    - Make sure to use a fan with a low-noise propeller type, and it should be able to blow a sufficient air for

      condensation.

    - It has sufficient strength for the required RPM, and performs static and dynamic balance tests for a quiet

      operation.

    - The motor is insulation class F, and its structure and general characteristics are in accordance with KSC

      4201~4206 conformity.

    - The drive method is a direct connection method.

    5) Control box and operation panel

    - Make it possible to display various operating conditions of the device. (run/stop, defrost timer switch,

      temperature controller, thermometer and various indicators)

    - All parts should have no abnormality in the withstand voltage test.

     

    6) Evaporator

    - The thermocouple must be a seamless phosphorus deoxidized copper tube (KSD 5301) or equivalent

      with a purity of 99% or higher, and there should be the uniformity of the copper tube and no harmful

      defects in use.

    - As for the copper tube and the FIN, these are mechanically expanded and closely contacted so that they

      have sufficient  thermal contact surface.

    - It uses the FIN which is 0.11T of Aluminum foil with a purity of 99.9% or higher. It should be coated with

      thermosetting resin on FIN in order to improve excellent corrosion resistance and thermal efficiency.

    - It should be implemented for the pressure test at 22kg/cm2.G, and the airtight test at a pressure of 

      15kg/cm2.G or above. There should be no abnormalities such as leakage and deformation.

    7) Fan for Evaporator 

    Make sure to use a fan with a low-noise propeller type, and it should be able to blow a sufficient air for

      condensation.

    - It has sufficient strength for the required RPM, and performs static and dynamic balance tests for a quiet 

      operation.

    - The motor is insulation class F, and its structure and general characteristics are in accordance with

      KSC 4201~4206 conformity.

    - The drive method is a direct connection method.

    8) Piping for Refrigerant 

    - For the thermocouple, use a non-seamless phosphorus deoxidized copper tube (KSD 5301) with a

      purity over 99% or equivalent one, and there should be uniformity of the copper tube and no harmful

      defects in use.

    - Make sure to be minimized bends during piping work.

    - After the piping is installed, perform a leak test with nitrogen gas to confirm no abnormality.

    9) Insulation for Refrigerant pipe 

    - Insulation of the pipe is made as the same size as the copper pipe.

    - Make sure that there are no cracks in the seam of the insulation material.

    - Insulation is carried out by wrapping with primary vinyl, insulating secondary, and applying maximum

      pressure with the tape for cooler. (Pipe is applied when installing outdoor unit)

    10) Protection device

    - Over current relay, Module, Fusible plug, Fuse

    - Expansion valve

    - Use a thermostatic expansion valve or capillary tube (2.2~2.6mm).

    - When using a thermosensitive type, be careful about the sensing point.

    - When using a capillary tube, wind it using a 50mm tube and install it.

    - Insert the capillary tube sufficiently into the pipe to avoid clogging the welding area before welding.

    11) Defrost water evaporator

    - Create a clean and hygienic environment by installing a forced or automatic evaporator

    12) Scope of supply

      - Supplier

         Assembling the mortuary refrigerator Trial run

      - User

        Foundation work

        Primary side electrical wiring work

        Installation of sewage facilities and trenches to allow drainage during floor clean

    Unit of 2 Body Mortuary refrigerator (Body cabinet, Body refrigerator, Body freezer, Morgue refrigerator, Morgue freezer, Mortuary freezer, Mortuary refrigerators) installation

     

    SejongB/D 4F, #229-8, Kuui-Dong, Kwangjin-Ku, Seoul 143-823 Korea

      Tel : (822) 3437-8661   Fax : (822) 3436-6711   E-mail : sseon2010@hanmail.net

        Mobile phone : 82-10-6410-7577   Manufacture plant    E-mail :  j84416@gmail.com

     
     

     